Construction system help documents

Construction system help documents

Reinforcement for supporting outer wall at refill of soil

Distance between
partition wall
Concrete thickness Vertical reinforcement, centric Horizontal reinforcement, both sides
A B
7m 140mm 10mm CC 250 12mm CC 300 12mm CC 200
or
16mm CC 300
190mm 10mm CC 250 12mm CC 400 12mm CC 400
8m 140mm 10mm CC 250 12mm CC 200
or
16mm CC 300
12mm CC 200
or
16mm CC 300
190mm 10mm CC 250 12mm CC 300 12mm CC 200
or
16mm CC 300
9m 190mm 10mm CC 250 12mm CC 200
or
16mm CC 300
12mm CC 200
or
16mm CC 300
10m 190mm 12mm CC 250 12mm CC 200
or
16mm CC 300
12mm CC 200
or
16mm CC 300

 

  • A: Filling height max. 2.0 meters. Wall height min 2.4 meters
  • B: Filling height max. 2.5 meters. Wall height min 3.0 meters
  • : The top plastic bridge must additionally have 2x12mm which is placed in the lower part of the plastic bridge
  • : In the first two layers, it should be 2×12 mm on both the upper and lower part of both plastic bridges. Total 8x2x12 mm divided into two layers.

 

 

Reinforcement for carrying outer wall with light filling.

Filling height max 2,5 meters. Wall height min. 2,4 meters.

Distance between
partition walls
Concrete thickness Vertical reinforcement, centric Horizontal reinforcement, both sides
7m 140mm 10mm CC 300 10mm CC 300
190mm 10mm CC 300 10mm CC 300
8m 140mm 10mm CC 300 12mm CC 300
190mm 10mm CC 300 12mm CC 300
9m 190mm 12mm CC 300 12mm CC 300
10m 190mm 12mm CC 300 12mm CC 300